STI Vibration Monitoring, Inc. Vibration Monitoring & Machine Protection Systems
1010 East Main Street, League City, TX 77573
www.stiweb.com / www.stiwebstore.com
Tel 281.334.0766   
Toll Free 888.777.7213   
Fax 281.334.4255   
Sensors - Vibration Monitors - Vibration Transmitters - Protection Systems - Junction Boxes - BNC Switch Boxes - Sensor Cables - Mounting Hardware - Rotor Kits - Balancing Kits

Products

Vibration Calculator

Follow us on FacebookFollow us on TwitterSTI Vibration Monitoring YouTube

CMCP540 Proximity Probe In/ Displacement Out Transmitter/Monitor

Field Application Note: Differential Expansion TSI

Vibration Displacement Transmitters

         Features:

  • Low Cost
  • Small Size
  • DIN Rail Mount
  • Proximity Probe Input
  • 4-20 mA Output
  • Fault Detection
  • Buffered Transducer Output
  • Filter Option
  • CSA & UL Approved
  • Class I Division II
  • CE Approved Approved

Download Data Sheet in PDF Format Manual Quick Start Tech Note CE Declaration CSA / UL Hazardous Area Approved

CMCP540 Vibration Displacement Transmitters

CMCP 500 Transmitter Approval Label

Description:

The CMCP540 Vibration Displacement Transmitters are compatible with proximity probe input, and they provide a 4-20 mA output proportional to the overall measurement. Each unit processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to a user specified range such as 5 mils peak to peak. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.

Buffered Output:

A BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. This includes both the unfiltered vibration signal, and the DC bias voltage. Portable test equipment or analyzers like SKF-CM's Microlog™ can be connected to this output without disturbing other system outputs.

Fault Detection:

On board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to 2 mA to indicate the fault to the readout system. A red LED on the front of the unit is turned on to provide a local indication of the fault.

Filters:

For applications that require monitoring specific frequency bands, optional high-pass and low-pass filters can be specified. These filters are modular and can be installed by the factory or in the field. Each module attenuates out-of-band signals at a rate of approximately 24 dB/octave. Corner frequencies from 2 Hz to 20 kHz may be specified. Filter modules may be cascaded to form higher order filters or to create a band-pass response. Filtering does not effect the buffered transducer output.

Alarms:

The CMCP540 Vibration Displacement Transmitters do not have any alarm features. For alarms we have the CMCP540A Vibration Displacement Monitors.

Alarms relays and trip multiply are available with the Monitor version.

Alarms - The CMCP500A Series Monitors have two independent set points, with LED alarm indicators and output relay contacts (Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110% of full scale. Each has an adjustable delay of 1 to 10 seconds. SPST Relay contacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads.

Relay contacts can be independently configured by the user for either Normally Open (NO) (Standard) or Normally Closed (NC) operation. Relays are normally de-energized and can be configured for latching or non-latching (standard) operation. Latched alarms may be reset locally or by remote contact closure.

Trip Multiply - The monitors have set point multiplication of 3X via contact closure (2X available). To avoid tripping the alarms during machine start-up.

Displays And Assemblies:

Various display options, NEMA and explosion-proof enclosures, and assembled multi-channel systems are available. Consult your sales representative.

Electrical Specifications:

Power: +24 Vdc @ 45 mA max. (30 mA typical at 2 full scale output). Reverse polarity and transient protection   included.(With the Alarm/Relay option installed: 75 mA max.)
Frequency Response (Without optional filters): (-3 dB) 2 Hz to 20 kHz.
Buffered Output: BNC Connector 0-20 kHz.
Accuracy: 1.0 % of Full Scale Range.
Output: 4-20 mA proportional to the full scale range.
Maximum Load: 600 Ohms Resistive.
Case: Isolated

Environmental Specifications:

Operating Temp.: -20°C to +80°C (-4°F to +176°F).
Storage Temp.: -55°C to +125°C (-67°F to +257°F).
Relative Humidity: 0 - 95% Non-Condensing.

Mounting:

32 mm (G style) or 35 mm (T style) DIN Rail.

Ordering Example:

To order a standard acceleration monitor that accepts input from a 100 mV/mil Proximity Probe with a Full Scale of 5 mils peak to peak detection, specify Part Number: CMCP540-100-01.

NOTES:

  1. To order factory installed 4-pole filter modules, add the appropriate suffix to the basic part number:

    1. Example: adding suffix -L500 specifies a 4-pole low-pass filter with a corner frequency of 500 Hz (30,000 cpm). Adding suffix - H40 specifies a 4-pole High-Pass filter with a corner frequency of 40 Hz (2400 cpm). Up to two filter modules may be specified. Filter modules can be field installed. If you are unsure about your filter needs, need higher order filters or a band-pass response, consult the factory or your regional sales office for assistance in specifying the correct option numbers.

  2. The Full Scale option specified at order entry is used by the factory for initial calibration. However, several other ranges can be jumper selected in the field.

  3. Transducer and Full Scale options not listed in the above table are available. Contact your sales representative.

CMCP540 Vibration Displacement Transmitter
CMCP540A Vibration Displacement Monitor

CMCP540(A)-(aaa)-(bb)-(ccc)-(dddd)

(aaa) Input
100, 100 mV/mil
200, 200 mV/mil
Specify, Specify Exact mV/mil

(bb) Full Scale
01, 5 mils Peak to Peak
02, 10 mils Peak to Peak
03, 15 mils Peak to Peak
51, 125 micron Peak to Peak
52, 250 micron Peak to Peak
53, 375 micron Peak to Peak
Specify, Specify in 5 mil Increments

(ccc) Optional High Pass Filter
HXX, High Pass Corner Frequency in Hz

(dddd) Optional Low Pass Filter
LXXX, Low Pass Corner Frequency in Hz

 

Copyright © 2014 STI Vibration Monitoring Inc. All Rights Reserved.