STI Vibration Monitoring, Inc. Vibration Monitoring & Machine Protection Systems
1010 East Main Street, League City, TX 77573
www.stiweb.com / www.stiwebstore.com
Tel 281.334.0766   
Toll Free 888.777.7213   
Fax 281.334.4255   
Sensors - Vibration Monitors - Vibration Transmitters - Protection Systems - Junction Boxes - BNC Switch Boxes - Sensor Cables - Mounting Hardware - Rotor Kits - Balancing Kits

Products

Vibration Calculator

Follow us on FacebookFollow us on TwitterSTI Vibration Monitoring YouTube

CMCP525 Vibration Acceleration Transmitter/Monitor

Field Application Note: Differential Expansion TSI

Vibration Acceleration Transmitters

         Features:
  • Low Cost
  • Small Size
  • DIN Rail Mount
  • 100 mV/g, Accelerometer Input
  • 4-20 mA Output
  • Fault Detection
  • Buffered Transducer Output
  • Filter Option
  • CSA & UL Approved
  • Class I Division II
  • CE Approved Approved

Download Data Sheet in PDF Format Manual Quick Start Tech Note CE Declaration CSA / UL Hazardous Area Approved

CMCP525 Vibration Acceleration Transmitters

CMCP500 Transmitter Approval Label

Description:

The CMCP525 Vibration Acceleration Transmitters are compatible with all voltage output accelerometers, and they provide a 4-20 mA output proportional to the overall measurement. Each unit provides power for the associated transducer, processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to a user specified range such as 0-5 g's in Peak or RMS detection. Combining transmitters with an existing PLC or DCS system results in a high density, low cost vibration monitoring system.


Buffered Output:

A BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. This includes both the unfiltered vibration signal, and the DC bias voltage. Portable test equipment or analyzers like SKF-CM's Microlog™ can be connected to this output without disturbing other system outputs.


Fault Detection:

On board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to 2 mA to indicate the fault to the readout system. A red LED on the front of the unit is turned on to provide a local indication of the fault.


Filters:

For applications that require monitoring specific frequency bands, optional high-pass and low-pass filters can be specified. These filters are modular and can be installed by the factory or in the field. Each module attenuates out-of-band signals at a rate of approximately 24 dB/octave. Corner frequencies from 2 Hz to 20 kHz may be specified. Filter modules may be cascaded to form higher order filters or to create a band-pass response. Filtering does not effect the buffered transducer output.


Alarms:

The CMCP525 Vibration Acceleration Transmitters do not have any alarm features. For alarms we have the CMCP525A Vibration Acceleration Monitors.

Alarms relays and trip multiply are available with the Monitor version.

Alarms - The CMCP500A Series Monitors have two independent set points, with LED alarm indicators and output relay contacts (Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110% of full scale. Each has an adjustable delay of 1 to 10 seconds. SPST Relay contacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads.

Relay contacts can be independently configured by the user for either Normally Open (NO) (Standard) or Normally Closed (NC) operation. Relays are normally de-energized and can be configured for latching or non-latching (standard) operation. Latched alarms may be reset locally or by remote contact closure.

Trip Multiply - The monitors have set point multiplication of 3X via contact closure (2X available). To avoid tripping the alarms during machine start-up.


Displays And Assemblies:


Various display options, NEMA and explosion-proof enclosures, and assembled multi-channel systems are available. Consult your sales representative.


Electrical Specifications:

Power: +24 Vdc @ 45 mA max. (30 mA typical at 2 full scale output). Reverse polarity and transient protection   included.(With the Alarm/Relay option installed: 75 mA max.)
Frequency Response (Without optional filters): (-3 dB) 2 Hz to 20 kHz.
Buffered Output: BNC Connector 0-20 kHz.
Accuracy: 1.0 % of Full Scale Range.
Output: 4-20 mA proportional to the full scale range.
Maximum Load: 600 Ohms Resistive.
Case: Isolated.

Environmental Specifications:

Operating Temp.: -20°C to +80°C (-4°F to +176°F).
Storage Temp.: -55°C to +125°C (-67°F to +257°F).
Relative Humidity: 0 - 95% Non-Condensing.

Mounting:

32 mm (G style) or 35 mm (T style) DIN Rail.

Ordering Example:

To order a standard acceleration transmitter that accepts input from a 100 mV/g Accelerometer, with a Full Scale of 10 g with Peak Detection, specify Part Number: CMCP525-100A-02P.

NOTES:

  1. To order factory installed 4-pole filter modules, add the appropriate suffix to the basic part number:

    1. Example: adding suffix -L500 specifies a 4-pole low-pass filter with a corner frequency of 500 Hz (30,000 cpm). Adding suffix - H40 specifies a 4-pole High-Pass filter with a corner frequency of 40 Hz (2400 cpm). Up to two filter modules may be specified. Filter modules can be field installed. If you are unsure about your filter needs, need higher order filters or a band-pass response, consult the factory or your regional sales office for assistance in specifying the correct option numbers.

  2. The Full Scale option specified at order entry is used by the factory for initial calibration. However, several other ranges can be jumper selected in the field.

  3. Transducer and Full Scale options not listed in the above table are available. Contact your sales representative.

CMCP525 Vibration Acceleration Transmitter
CMCP525A Vibration Acceleration Monitor

CMCP525(A)-(aaa)-(bbb)-(ccc)-(dddd)

(aaa) Input
100, 100 mV/g Accelerometer
Specify, Specify Exact mV/g

(bbb) Full Scale
01R, 0 to 5 g, RMS Detection
01P, 0 to 5 g, Peak Detection
02R, 0 to 10 g, RMS Detection
02P, 0 to 10 g, Peak Detection
Specify, Specify in 5 g Increments, Followed by R or P

(ccc) Optional High Pass filter
HXX, High Pass Corner Frequency in Hz

(dddd) Optional Low Pass Filter
LXXX, Low Pass Corner Frequency in Hz

 

Copyright © 2014 STI Vibration Monitoring Inc. All Rights Reserved.