Products
|
|
CMCP1210
Spring Loaded Temperature Sensors |
|
Features:
• Tip Sensitive RTD or
Thermocouple
• For use to 260° C (500° F)
• Adjustable Spring-Loaded Holder
with Fluid Seal
• Aluminum or Stainless Steel Connection Head
• For Bearings, Blocks and Other
Solids
• Explosion Proof Version
Available All Parts FM Approved - Conduit
Head, Spring Loaded Probe
Holder, and Probe
|
The CMCP1210 series
bearing temperature sensor provides, fast and accurate readings from bearings,
blocks, and other solids. The spring-loaded holder ensures solid contact in
drilled holes with a built-in oil seal. The sensing probe features a copper
alloy tip for quick response to temperature changes. Probes may be cut to
length in the field using a tube cutter. |
Specifications:
Temperature range: |
-50° to 260° C
(-58° to 500° F) |
Material: |
|
Probe: |
SS with Copper Alloy Tip |
Holder: |
Stainless Steel with Viton
O-ring
|
Head: |
Aluminum or Stainless Steel |
Pressure rating: |
50 psi (3.4 bar) |
Insulation resistance: |
10 megohms min. at 100 Vdc,
leads to case.
Ungrounded junctions only on thermocouples. |
Connection: |
Terminal block for wires to 14
AWG |
Conduit thread: |
1/2" NPT |
Bearing entry: |
1/2" NPT (For 3/4" NPT, use
optional CMCP1211 Adapter. Add 1" to length for adapter.) |
Time constant: |
|
Typical value in moving water: |
2.0 seconds |
Standard Version:
Temperature Probe |
RTD |
Thermocouple |
Probe Diameter: 0.250"
Temperature range: -50 to 260°C (-58 to
500°F).
Case: Stainless steel
with copper alloy tip.
Time constant: 2.0 seconds
typical in moving water. 3.0 seconds for dual
element models.
Pressure rating: 100 psi (6.9
bar).
Insulation
resistance:
- Single element
probes: 1000 megohms min. at 500 VDC, leads to case.
- Dual element probes: 100 megohms min. at 100 VDC, between
elements and leads to case.
Vibration: Withstands 10 to
2000 Hz at 20 G's min.
Shock: Withstands 100
G's min. sine wave shock of 8
milliseconds duration. |
Probe Diameter: 0.250"
Temperature range: -184 to 260°C (-300
to 500°F).
Case: Stainless steel
with copper alloy tip. On special order.
Time constant:
Typical value in
moving water:
- Grounded junction: 1.5 seconds.
- Ungrounded junction: 7 seconds.
Pressure rating: 100 psi (6.9 bar).
Insulation
resistance: 10 megohms min. at 100 VDC, leads to case, ungrounded
junctions only.
Vibration: Withstands 10 to
2000 Hz at 20 G's min.
Shock: Withstands 100
G's min. sine wave shock of 8
milliseconds duration. |
|
Spring Loaded Probe Holder |
Spring-loaded
holders provide a quick and simple installation of probe sensors pull out
and twist the knob, insert the probe until it bottoms out, and release the
knob. Spring pressure holds the probe tip in contact with the measuring
surface for faster response and more reliable measurements. Features a
rubber O-ring that doesn't crimp the probe but prevents oil leakage to 50
psi (3.4 bar) at up to 260°C.
Body material: 300 series stainless
steel
Temperature range: -40 to 260°C (-40 to
500°F)
Thread (Conduit
Head): 3/4 - 14 NPT
Thread (Case Mount): 1/2 - 14 NPT
Hex size: 1 1/8" (29 mm)
|
Conduit Head |
Body/gasket
material: Aluminum/silicone
gasket
IP/NEMA Rating: IP55 Type 3 and 4
Max. Temp.: 316°C (600°F)
Dimensions: H - 3.5 (89)
L - 3.5 (89)
D - 2.0 (51)
T - 1.75 (44)
|
XP
Version:
Conduit Head |
Aluminum Alloy 356 T6 |
FM/CSA Approved |
Connection head is suiable for use in harardous locations as defined by the national and Canadian electrical codes as:
-
Class I, Groups B,
C, AND D; Class II, Groups E, F, and G,
-
T6 (Ta = 40°C), T2
(Ta = 260°C) Ta limited to 160°C for CSA Class II
-
Class I, Zone 1,
AEx\Ex d IIC T6 (Ta = 40°C), T2 (Ta = 260°C);
-
With O-ring in place, the connection head is suitable for weatherproof applications defined as type 3 and 4.
-
Ingress protection of IP65.
|
Spring Loaded Probe Holder |
Stainless Steel |
-
Holder is equipped with a double containment system which has two O-ring seals that seal around the probe. If the first O-ring is breached, the fitting will leak via the weep hole. The second O-ring will keep measured medium frmo reaching electrical components.
-
O-ring material: Viton
-
Temperature limit: 260°C (500°F) maximum.
-
Pressure: Holder will withstand 50 PSIG at maximum temperature without any leaks around the O-ring seal.
|
Temperature Probe |
- Element: Platinum
-
Temperature limits: -50°C to 260°C (-58°F to 500°F)
-
Insulation resistance: 1000 MEGOHMS minimum at 500 volts DC, leads to probe case. Dual element only: 100 MEGOHMS at 100 volts DC, between elements.
-
Leads: AWG #26,
stranded, TFE insulated.
-
Case: Stainless steel, with copper alloy tip.
-
0.236 ±.005 [6.00 ±0.13] for this length only.
-
The PD and PA
resistance thermometers will meet the resistance-temperature relationship and tolerances specified in IEC
751, Class B.
-
Probe is suitable for use in harardous locations defined by
CENELEC EN 50 014
and EN50 018, EEx d IIC T6.
|
Complete Assembly |
-
The assembly is suitable for use in hazardous locations defined as follows:
-
National and Canadian Electrical Codes: Class I, Groups B, C, and D; Class II Groups
E, F and G, T6 (Ta = 40°C), T2 (Ta = 260°C), Ta limited to 160°C for CSA
Class II;
-
National Electrical code (NEC 505):C°C I, Zone 1, AEx d IIC T6 (Ta = 40°C), T2
(Ta = 260°C);
-
Canadian Electrical Code (IEC):Ex d IIC T6 (Ta = 40°C), T2 (Ta = 260°C).
- Temperature range:
-50°C TO 260°C
- Insulation resistance: 100 MEGOHMS minimum at 100 volts DC, leads to probe case.
- The PD resistance thermometer will meet the resistance-temperature relationship and tolerances specified in EN 60751 (IEC 751), Class B.
- Connection: Terminal board for sires up to AWG #14.
- Adjustable spring-loaded option is equippend with two O-ring seals. It was a weep hole between the primary and secondary O-ring seals to indicate failure of the primary seal.
- The G1/2A thread form will meet the following specification: ISO 228/1, DIN 259, BS2779 and
JIS B0202. Process connection end configuration per DIN 3852, Part 2 Type
A (Stub end).
|
Ordering Information:
CMCP1210
|
-XX |
-X.X |
-XX |
Description |
|
- PA |
|
|
RTD -
Platinum 392, 100 Ohm (US) |
|
- PE |
|
|
RTD -
Platinum 385, 100 Ohm (Meets DIN, EIC, Cl B) |
|
- J |
|
|
Type J Iron-Constant Thermocouple |
|
- K |
|
|
Type K Chromel-Alumel Thermocouple |
|
|
- 8.4 |
|
8.4" Standard Insertion Depth (Field Cut) |
|
|
- X.X |
|
Insertion Depth - Specify 0.1" Increments (Max 8.4") |
|
|
|
-00 |
Standard Version
1/2" NPT Mount |
|
|
|
-01 |
XP Version, Aluminum
Head ClassI DivI, 50 psi-1/2"NPT |
|
|
|
-02 |
XP Version,
Stainless Steel Head ClassI DivI, 50 psi-1/2"NPT |
CMCP1211 |
|
|
|
1/2" NPT to 3/4" NPT