Description:
The CMCP585A Eccentricity Monitors are compatible with
proximity probe inputs, they provide a 4-20 mA output proportional to the
overall measurement. Each unit provides power for the associated
transducer, processes the vibration signal to determine overall amplitude,
and outputs a 4-20 mA dc current that is proportional to a user specified
range such as 0-10 mils. Combining
monitors with an
existing PLC or DCS system results in a high density, low cost vibration
monitoring system. With the alarm feature, the unit functions
as a complete single channel monitor that includes alert and danger alarms,
and output relays.
Buffered Output:
A BNC connector mounted on the front
of the unit provides access to the buffered transducer output signal. This
includes both the unfiltered vibration signal, and the DC bias voltage.
Portable test equipment or analyzers like SKF-CM's
Microlog™ can be connected to this output without disturbing
other system outputs.
Fault Detection:
On board fault detection circuitry
continuously monitors the transducer for normal operation. If a fault
occurs, the output current is reduced to 2 mA to indicate the fault to the
readout system. A red LED on the front of the unit is turned on to provide a
local indication of the fault.
Alarms:
This monitoring option adds
two independent set points, with LED alarm indicators and output relay
contacts (Alert and Danger). Set points are adjustable via potentiometer,
from 0 to 110% of full scale. Each has an adjustable delay of 1 to 10
seconds. Relay contacts can be independently configured by the user for
either Normally Open (NO) (Standard) or Normally Closed (NC) operation.
Relays are normally de-energized and can be configured for latching or
non-latching (standard) operation. Latched alarms may be reset locally or by
remote contact closure. SPST Relay contacts are rated 5 Amps @ 30 Vdc or 250
Vac for resistive loads. The Alarm option also provides set point
multiplication of 3X via contact closure (2X available).
Displays And Assemblies:
Various display options, NEMA
and explosion-proof enclosures, and assembled multi-channel systems are
available. Consult your sales representative. Monitoring Systems
Electrical Specifications:
-
Power: +24 Vdc @ 45 mA max.
(30 mA typical at 2
full scale output). Reverse polarity and transient protection included. (With the Alarm/Relay option installed: 75 mA max.)
-
Frequency Response: 30 cpm to 300 cpm
-
Buffered Output: BNC Connector
-
Accuracy: 5.0 % of Full Scale Range
-
Output: 4-20 mA proportional to the full scale range
-
Maximum Load: 600 Ohms Resistive
-
Case: Isolated
Environmental Specifications:
-
Operating Temp.: -20°C to +80°C
(-4°F to +176°F)
-
Storage Temp.: -55°C to +125°C (-67°F
to +257°F)
-
Relative Humidity: 0 - 95% Non-Condensing
Mounting:
32 mm (G style) or 35 mm (T style) DIN Rail
Ordering Example:
To order a standard
eccentricity monitor that accepts input from a 200 mV/mil proximity probe
system, with a Full Scale of 0-10 mils,
specify Part Number: CMCP585A-01-02.
NOTES:
- The Full Scale option
specified at order entry is used by the factory for initial calibration.
However, several other ranges can be jumper selected in the field.
- Transducer
and Full Scale options not listed in the above table are available.
Contact your sales representative.
Ordering
Information:
Eccentricity Monitor/Transmitter CMCP585
CMCP585(X)-(aaa)-(bb)
CMCP585
Eccentricity Transmitter
CMCP585A Eccentricity Monitor
(aa) Input
01, 200 mV/mil
Specify, Specify Exact mV/mil
(bb) Full Scale
01, 0-5
mils
02, 0-10 mils
03,
0-15 mils
04, 0-20 mils
05, 0-25 mils
51, 0-125 µm
52, 0-250 µm
53, 0-375 µm
54, 0-500 µm
55, 0-625 µm
|