CMCP5019 Rack Mounted 10-Channel
Monitor |
|
Features:
• 19" EIA
Rack or Panel Mount
• Individual Bright Red LED Displays
• OK, Alert, and Danger Relays
- API-670
• CE Approved
• Terminals for Customer Wiring
• 110 or 120 VAC Power
• Optional Power Supply for Eddy Probes
• Optional Digital Communication |
As customers increasingly seek to replace existing
and obsolete rack mounted monitoring systems, we have been asked to provide an
integrated solution to make replacement simple and easy.
The CMCP5019 10 Channel Monitor is precisely
designed for direct and simple replacement of antiquated rack mounted monitoring
systems. The CMCP5019 mounts in any 19" EIA rack, or can be panel mounted in a
cutout. At 19" wide, 7" (2 DIN) high and 7.5" deep the unit is compact, while
remaining feature rich. As with any CMCP-500 Series System, the CMCP-5019 can be
stacked for unlimited channel counts.
Outputs Include:
- Common Relay Outputs: OK, Alert, and Danger
- 4-20 mA Recorder Outputs
- Buffered Dynamic Signal Output (BNC and
Terminal)
- Optional Digital Communications using Modbus
RS-485 or Modbus TCP (Ethernet)
Dimensions:
- Overall - 19" W x 7" H x 7.5" D (48.2 x 17.8 x
19 cm)
- Weight - 11 lbs w/Digital Communications (5
kg)
- Cutout Size - 17.75" x 7" (45.1 x 17.8 cm)
Installation:
Existing wiring is removed from the monitoring
system and terminated on the replaceable terminals on the back panel of the
CMCP5019. Power is provided by an integral 24 VDC power supply that accepts 110
or 220 VAC, 50 or 60 Hz. With the use of the front accessible selector switches
and the local displays, Current Value, Alert Set Point, and Danger Set Point can
be viewed and easily changed.
If replacing a monitoring system with less then 10
channels, blank CMCP500 Series Monitors and Displays will be provided for the
unused positions. Additional channels can be added at a later date as the
CMCP5019 is pre-wired for all 10 positions.
Ordering:
-
One (1) CMCP5019 10 Channel Monitor
-
Select the channel count (1-10)
-
Select communication option
-
Select a -24 VDC power supply if required for
eddy probes
-
Itemize the CMCP500 series monitors in the
order (left to right) they will be installed. We will determine display values
from the monitor part numbers.
|
Ordering Information:
CMCP5019 |
-XX |
-XX |
-XX |
10
Channel Rack Mounted Monitor |
|
-01 |
|
|
1
Display, 9 Blanks |
|
-02 |
|
|
2
Displays, 8 Blanks |
|
-03 |
|
|
3
Displays, 7 Blanks |
|
-04 |
|
|
4
Displays, 6 Blanks |
|
-05 |
|
|
5
Displays, 5 Blanks |
|
-06 |
|
|
6
Displays, 4 Blanks |
|
-07 |
|
|
7
Displays, 3 Blanks |
|
-08 |
|
|
8
Displays, 2 Blanks |
|
-09 |
|
|
9
Displays, 1 Blank |
|
-10 |
|
|
10
Displays |
|
|
-00 |
|
No
Digital Communication |
|
|
-RS |
|
Modbus RS-485 |
|
|
-ET |
|
Modbus TCP (Ethernet) |
|
|
|
-00 |
Without -24 VDC Aux. Supply |
|
|
|
-24 |
With
-24 VDC Aux. Supply |
*Order CMCP500 Series Monitors Separately
|