Description:
The CMCP797 Active Signal Buffer with a Single Input and four (4) Active Buffered Outputs accepts either a Accelerometer Input or Eddy (Proximity) Probe Input. It is powered with either +24 VDC for Accelerometers or -24 VDC for Eddy (Proximity) Probes. The CMCP797 has a jumper selectable CCD (Constant Current Diode) if powering of the Accelerometers is required. A front panel BNC connector is provided for portable data collectors and analyzers and is shared with Channel 4.
Accuracy: .1% Basic DC and AC
Input: Single +24VDC ICP Accelerometer (4mA constant current power provided) or -24VDC powered Proximity Systems
Output: Four (4) Active Buffered Outputs, Front Panel BNC Connector, Green Power "On" LED
Power: +24VDC for ICP Type Sensors, -24VDC for Proximity Systems, Connections via Front Terminal or DIN Rail Tbus Connection
Mounting: DIN Rail (35mm) Standard
Dimensions: 3.9" High x 0.89" Wide x 4.18" Deep (99 x 22.5 x 106mm)
|