Buffered Output - A BNC connector mounted on the front
of the unit provides access to the buffered transducer output signal. This
includes both the unfiltered vibration signal, and the DC bias voltage.
Portable test equipment or analyzers like SKF-CM's
Microlog™can be connected to this output without disturbing
other system outputs. Fault Detection - On board fault detection circuitry
continuously monitors the transducer for normal operation. If a fault
occurs, the output current is reduced to 2 mA to indicate the fault to the
readout system. A red LED on the front of the unit is turned on to provide a
local indication of the fault.
Filters - For
vibration monitoring applications that require
monitoring specific frequency bands, optional high-pass and low-pass
filters can be specified. (Only available on vibration models)
Alarms - The CMCP500A Series Monitors
have
two independent set points, with LED alarm indicators and output relay
contacts (Alert and Danger). Set points are adjustable via potentiometer,
from 0 to 110% of full scale. Each has an adjustable delay of 1 to 10
seconds. SPST Relay contacts are rated 5 Amps @ 30 Vdc or 250
Vac for resistive loads.
Relay contacts can be independently configured by the user for
either Normally Open (NO) (Standard) or Normally Closed (NC) operation.
Relays are normally de-energized and can be configured for latching or
non-latching (standard) operation. Latched alarms may be reset locally or by
remote contact closure.
Trip Multiply - The monitors have set point
multiplication of 3X via contact closure (2X available). To avoid tripping
the alarms during machine start-up.
Displays And
Assemblies - Various display options, NEMA
and explosion-proof enclosures, and assembled multi-channel systems are
available. |